Product Overview
The RVVSP series layers two complementary noise-control technologies onto the proven RVV construction: pair twisting plus a tinned copper braided shield with drain wire, all under a smooth PVC sheath. Produced to GB / T 5023 and JB / T 8734 series constructions with Class 5 finely stranded copper conductors, it is the reference choice when an Instrument Signal cable has to survive beside drives, contactors and radio equipment.
The twist cancels magnetically coupled, common-mode noise; the braid - held at ≥ 80 % optical coverage - blocks electrostatically coupled interference. Together they make RVVSP the classic Noise Reduction Cable for differential buses and analog loops, and the Shielded Twisted Pair Wire that system integrators standardise for RS-485, CAN and Modbus RTU networks across the plant.
Key Features
Twisted-pair construction with controlled lay length for common-mode rejection
Tinned copper braid shield with drain wire, ≥ 80 % coverage
Class 5 flexible stranded bare copper per IEC 60228 / GB / T 3956
Colour-coded pair insulation for error-free termination
300 / 500 V rating with 2,000 V routine test voltage
Flame retardant per IEC / EN 60332-1-2
2 – 30 cores (1 – 15 pairs); 0.3 – 1.5 mm²
Technical Specifications
|
Parameter |
Specification |
|
Conductor |
Flexible stranded bare copper, Class 5, IEC 60228 / GB / T 3956 |
|
Pairing |
Cores twisted in pairs, controlled lay length |
|
Shield |
Tinned copper braid + drain wire, ≥ 80 % coverage |
|
Insulation / sheath |
PVC / PVC, grey or black |
|
Core range |
2 – 30 cores (1 – 15 pairs); 0.3 – 1.5 mm² |
|
Rated voltage |
300 / 500 V |
|
Test voltage |
2,000 V AC |
|
Min bending radius |
6 × OD flexing; 4 × OD fixed |
|
Operating temperature |
−15 °C to +70 °C flexing; −40 °C to +70 °C fixed |
|
Flame retardancy |
IEC / EN 60332-1-2 |
|
Reference standards |
GB / T 5023 · JB / T 8734 series · IEC 60227 equivalent |
|
Compliance |
CE · RoHS · REACH |
Typical Applications
RS-485, CAN and Modbus RTU field buses - the standard Shielded Twisted Pair Wire for multi-drop networks over long plant runs
4–20 mA, HART and RTD loops, where a stable Instrument Signal cable keeps readings drift-free beside VFDs
Elevator, crane and machine-tool control runs in electrically noisy plants - a proven Noise Reduction Cable route
Weighing systems, load cells and encoder / resolver feedback
Audio, public-address and intercom circuits that must stay hum-free
Laboratory and test-bench wiring near sensitive analyzers
Engineering & Quality Assurance
Copper is procured as 99.99 % purity rod and re-verified against IEC 60228 conductor resistance; pair lay length and braid tension are controlled so twist balance and shield continuity hold drum after drum. Each batch passes 100 % spark, high-voltage and conductor-resistance testing in our ISO 9001-certified plant and ships with traceable batch records, a factory test report and CE / RoHS / REACH documentation; SGS or TÜV inspection can be arranged for tenders.
Our engineers back every quotation with practical network advice: terminate RS-485 buses with 120 Ω resistors at both ends, ground the drain wire at the controller side to avoid ground loops, and keep bus runs separated from power cables in shared trays. Honest guidance like this is why integrators keep RVVSP in their standard parts list.
Why Source RVVSP From Us
Twist plus braid in one jacket: a true Noise Reduction Cable instead of field fixes
Factory-direct pricing with stable copper sourcing and short lead times
OEM / ODM support: custom pair counts, colours, printing and drum lengths
Free samples and complete technical datasheets for evaluation
Export packing: 100 m / 500 m drums or cut lengths on seaworthy pallets
Batch-level traceability and a replacement guarantee on any retest failure
Frequently Asked Questions
RVVSP or RVVP for my signal loops?
RVVP suits point-to-point analog loops and low-speed interfaces. When signals are differential - RS-485, CAN - or runs are long and noisy, the pair twist adds common-mode rejection that the braid alone cannot provide. We will tell you plainly which construction your topology needs.
How should the shield and pairs be terminated?
Connect the drain wire to signal reference at the controller end, fit 120 Ω bus termination where the standard requires it, and never leave the braid floating - an unterminated shield can couple more noise than none at all.
Which certifications ship with each order?
A CE Declaration of Conformity, RoHS and REACH statements and factory routine-test reports for every drum. Third-party inspection by SGS or TÜV can be arranged on request.
Order & Technical Support
Send your pair count, cross-section and quantity to our sales engineers. Within 24 hours you receive a datasheet, factory-direct pricing and a sample of the exact Shielded Twisted Pair Wire your network requires - a fully tested Instrument Signal cable that keeps every reading true.
Hot Tags: rvvsp twisted pair shielded instrument signal cable, China rvvsp twisted pair shielded instrument signal cable manufacturers, suppliers, factory