Product Overview
The RVVP series couples finely stranded Class 5 copper conductors with a tinned copper braided shield and drain wire under a smooth PVC sheath, produced to GB / T 5023 and JB / T 8734 series constructions. One production platform covers 2 – 30 cores from 0.3 to 2.5 mm², so a single supplier line serves everything from a lone transmitter drop to a dense marshalling cabinet. That breadth, held to tight electrical tolerances, is what makes the series a dependable Precision Instrument Cable for process plants, test benches and OEM instrumentation.
Weak signals cannot tolerate coupled noise. The braid holds ≥ 80 % optical coverage to keep 4–20 mA loops, RTD and load-cell readings stable beside drives and switchgear - the reason system integrators standardise on it as their shielded instrument cable of record. And because the cores stay supple and colour-coded, electricians treat it as a fast-terminating Measuring Meter Wire for panel- and field-side connections alike.
Key Features
Class 5 flexible stranded bare copper per IEC 60228 / GB / T 3956
Tinned copper braid shield with drain wire, ≥ 80 % coverage
Wide core range: 2 – 30 cores; 0.3 – 2.5 mm² on one platform
Colour-coded PVC core insulation for error-free marshalling
300 / 500 V rating with 2,000 V routine test voltage
Flame retardant per IEC / EN 60332-1-2
Supple jacket for tight cabinet radii and trunking runs
Technical Specifications
|
Parameter |
Specification |
|
Conductor |
Flexible stranded bare copper, Class 5, IEC 60228 / GB / T 3956 |
|
Shield |
Tinned copper braid + drain wire, ≥ 80 % coverage |
|
Insulation / sheath |
PVC / PVC, grey or black |
|
Core range |
2 – 30 cores; 0.3 – 2.5 mm² |
|
Rated voltage |
300 / 500 V |
|
Test voltage |
2,000 V AC |
|
Min bending radius |
6 × OD flexing; 4 × OD fixed |
|
Operating temperature |
−15 °C to +70 °C flexing; −40 °C to +70 °C fixed |
|
Flame retardancy |
IEC / EN 60332-1-2 |
|
Reference standards |
GB / T 5023 · JB / T 8734 series · IEC 60227 equivalent |
|
Compliance |
CE · RoHS · REACH |
Typical Applications
Pressure, temperature and flow transmitters - a stable Precision Instrument Cable for 4–20 mA and HART loops
Weighing systems, load cells and energy meters, where a quiet Measuring Meter Wire preserves reading integrity
PLC analog I/O and marshalling cabinets, routed as a compact shielded instrument cable to keep cabinets hum-free
RTD and potentiometric sensor circuits in process and HVAC plants
Laboratory and test-bench wiring beside sensitive analyzers
Elevator, crane and machine-tool control circuits running near VFDs
Engineering & Quality Assurance
Copper is procured as 99.99 % purity rod and re-verified against IEC 60228 conductor resistance before stranding; the tinned braid is applied at controlled tension so coverage and shield continuity stay within spec across the whole core range. Every drum of shielded instrument cable passes 100 % spark, high-voltage and conductor-resistance testing in our ISO 9001-certified plant, with capacitance and transfer-impedance checks available on request. Shipments carry traceable batch records, a factory test report and CE / RoHS / REACH documentation; SGS or TÜV inspection can be arranged for tenders.
Our engineers back every quotation with practical EMC advice: ground the drain wire at the controller end to avoid ground loops, separate signal and power runs in shared trays, and upsize one cross-section for long analog loops. Honest guidance like this is why instrumentation contractors keep our line in their standard parts list.
Why Source This Series From Us
Factory-direct pricing with stable copper sourcing and short lead times
One platform, 2 – 30 cores: consolidate instrument cabling under a single supplier
OEM / ODM support: custom core counts, colours, printing and drum lengths
Free samples and complete technical datasheets for evaluation
Batch-level traceability and a replacement guarantee on any retest failure
Frequently Asked Questions
How do I choose the right core count?
Count field devices per loop group and add one spare core for maintenance. Because the series spans 2 – 30 cores on one construction, you can standardise on a single part family across the plant - simpler stocking, consistent stripping and termination.
RVVP or RVSP for my loops?
For point-to-point analog loops, weighing sensors and low-speed interfaces, RVVP is the cost-effective choice. For long differential buses such as RS-485 or CAN, twisted-pair RVSP controls crosstalk better - we say so plainly, because matching construction to signal type is part of correct instrumentation practice.
Which certifications ship with each order?
A CE Declaration of Conformity, RoHS and REACH statements and factory routine-test reports for every drum. Third-party inspection by SGS or TÜV can be arranged on request.
Order & Technical Support
Send your core count, cross-section and quantity to our sales engineers. Within 24 hours you receive a datasheet, factory-direct pricing and a sample of the exact Precision Instrument Cable your loops require - a fully tested Measuring Meter Wire that keeps every reading true.
Hot Tags: rvvp wide range core shielded instrument cable, China rvvp wide range core shielded instrument cable manufacturers, suppliers, factory




